All Liaison drivers are preloaded to the S3 and S5 units.  They are simply activated through a configuration file.  It may occasionally be required to upload an updated version of a driver but this is not a usual circumstance.

The implementation of certain network protocol drivers may not support every feature that the protocol specification offers.  Support for some legacy equipment or rarely used features may be absent.  Please check the driver specification documents to ascertain that the current driver version supports the features that you require.  In the event that a feature or support for a specific model of legacy equipment is omitted, please contact technical support (email is preferred) at support@liaisontech.com and let us know.  The Pronghorn architecture makes it a relative straightforward proposition to add supplemental functionality in very little time and Liaison is focused on delivering complete solutions rather than selling as-is product.

The following table list drivers either currently available or under development as well as a link to documentation on the drivers support for specific protocol features.  Click the <Features> link to confirm support for your application or call the technical support line if you are unsure.

 
 

Protocol

Modes

Docs

Vers.

Allen Bradley DF-1 RS-232/485 Master, Slave 0.0-50
Allen Bradley CSP Ethernet (PLC5) Ethernet Peer 0.0-80
Allen-Bradley CIP Ethernet (Controllogix) Ethernet Peer 0.0-00
Allen-Bradley Data Highway Plus Proprietary Peer 0.0-00
Allen-Bradley Data Highway Proprietary PLC3 command set  
Allen-Bradley Remote I/O Scanner Proprietary Master 0.0-00
Bar Code Reader (Keyence) RS-232/485 ASCII Selectable trigger, stop, fresh data indication bit

0.1-33

DeviceNet CAN Master, Peer, Slave

0.0-00

DNP 3.0 RS-232/485, Ethernet Master, Slave

0.0-00

ENRAF ENTIS Host Comms RS-232/485 ASCII

Master (Scripted bhavior)

0.1-43

Generic ASCII Serial (GAS) RS-232/485 ASCII Complete string check, fresh data indication bit

0.1-43

GE SNP RS-232/485    
GE SNPX RS-232/485    
GE HCS Ethernet    
Modbus RTU (Modicon) RS-232/485 master/slave, float request returned as two holding registers 0.3-181
Modbus RTU (Gould) RS-232/485 32 bit register support, master/slave 0.3-181
Modbus ASCII (Modicon) RS-232/485 master/slave, float request returned as two holding registers, ascii mode 0.3-181
Modbus ASCII (Gould) RS-232/485 32 bit register support, master/slave, ascii mode 0.3-181
Modbus ASCII (Danload) RS-485 Daniel Danload Support 0.3-181
Modbus Plus SA-85 Peer  
Modicon TCP/IP Ethernet Peer  
Profibus DP Slave RS-485 Proprietary Single slave, slave ID emulation, monitoring and virtual modes 0.0-00
Profibus DP Mulit-slave RS-485 (Proprietary) multiple slaves, slave ID emulation, monitoring and virtual modes 0.2-24
XML Ethernet  

0.0-00