All Liaison drivers are preloaded
to the S3 and S5 units. They are simply activated through a
configuration file. It may occasionally be required to upload an
updated version of a driver but this is not a usual circumstance. The
implementation of certain network protocol drivers may not support every
feature that the protocol specification offers. Support for some
legacy equipment or rarely used features may be absent. Please check
the driver specification documents to ascertain that the current driver
version supports the features that you require. In the event that a
feature or support for a specific model of legacy equipment is omitted,
please contact technical support (email is preferred) at support@liaisontech.com
and let us know. The Pronghorn architecture makes it a relative
straightforward proposition to add supplemental functionality in very
little time and Liaison is focused on delivering complete solutions rather
than selling as-is product. The
following table list drivers either currently available or under
development as well as a link to documentation on the drivers support for
specific protocol features. Click the <Features> link to
confirm support for your application or call the technical support line if
you are unsure.
|
|
Protocol
|
Modes
|
Docs
|
Vers.
|
| Allen
Bradley DF-1 |
RS-232/485 |
Master,
Slave |
 |
0.0-50 |
| Allen
Bradley CSP Ethernet (PLC5) |
Ethernet |
Peer |
 |
0.0-80 |
| Allen-Bradley
CIP Ethernet (Controllogix) |
Ethernet |
Peer |
 |
0.0-00 |
| Allen-Bradley
Data Highway Plus |
Proprietary |
Peer |
 |
0.0-00 |
| Allen-Bradley
Data Highway |
Proprietary |
PLC3
command set |
 |
|
| Allen-Bradley
Remote I/O Scanner |
Proprietary |
Master |
 |
0.0-00 |
| Bar
Code Reader (Keyence) |
RS-232/485
ASCII |
Selectable
trigger, stop, fresh data indication bit |

|
0.1-33 |
| DeviceNet |
CAN |
Master,
Peer, Slave |

|
0.0-00 |
| DNP
3.0 |
RS-232/485,
Ethernet |
Master,
Slave |

|
0.0-00 |
| ENRAF
ENTIS Host Comms |
RS-232/485
ASCII |
Master (Scripted
bhavior) |
|
0.1-43 |
| Generic
ASCII Serial (GAS) |
RS-232/485
ASCII |
Complete
string check, fresh data indication bit |

|
0.1-43 |
| GE
SNP |
RS-232/485 |
|
 |
|
| GE
SNPX |
RS-232/485 |
|
 |
|
| GE
HCS |
Ethernet |
|
 |
|
| Modbus
RTU (Modicon) |
RS-232/485 |
master/slave,
float request returned as two holding registers |
 |
0.3-181 |
| Modbus
RTU (Gould) |
RS-232/485 |
32
bit register support, master/slave |
 |
0.3-181 |
| Modbus
ASCII (Modicon) |
RS-232/485 |
master/slave,
float request returned as two holding registers, ascii mode |
 |
0.3-181 |
| Modbus
ASCII (Gould) |
RS-232/485 |
32
bit register support, master/slave, ascii mode |
 |
0.3-181 |
| Modbus
ASCII (Danload) |
RS-485 |
Daniel
Danload Support |
 |
0.3-181 |
| Modbus
Plus |
SA-85 |
Peer |
 |
|
| Modicon
TCP/IP |
Ethernet |
Peer |
 |
|
| Profibus
DP Slave |
RS-485
Proprietary |
Single
slave, slave ID emulation, monitoring and virtual modes |
 |
0.0-00 |
| Profibus DP
Mulit-slave |
RS-485
(Proprietary) |
multiple slaves, slave ID emulation, monitoring and virtual modes |
 |
0.2-24 |
| XML |
Ethernet |
|

|
0.0-00 |
|
|